Product Description
Ultramid C3U is an injection molding, general purpose PA6/66 grade with improved flame retardance. The product is UL recognized as 94V0 at 0.4 mm minimum thickness.
General  
Material Status 
  • Commercial: Active
Availability 
  • Europe
  • North America
 
Features 
  • Flame Retardant
  • Good Electrical Properties
  • Good Flow
  • Halogen Free
  • Low (to None) Phosphorus Content
  • Low Viscosity
Uses 
  • Electrical Parts
  • Electrical/Electronic Applications
  • Electronic Insulation
RoHS Compliance 
Appearance 
  • Colors Available
  • Natural Color
 
Forms 
  • Pellets
Processing Method 
  • Injection Molding
Multi-Point Data 
  • Creep Modulus vs. Time (ISO 11403-1)
  • Isochronous Stress vs. Strain (ISO 11403-1)
  • Isothermal Stress vs. Strain (ISO 11403-1)
  • Secant Modulus vs. Strain (ISO 11403-1)
  • Shear Modulus vs. Temperature (ISO 11403-1)
  • Viscosity vs. Shear Rate (ISO 11403-2)
Physical
Dry
Conditioned
Unit
Test Method
Specific Gravity
       
--
--
 
ASTM D792
--
--
g/cm³
ISO 1183
Melt Volume-Flow Rate (MVR) (275°C/5.0 kg)
--
in³/10min
ISO 1133
Molding Shrinkage - Flow (0.125 in)
--
in/in
ASTM D955
Water Absorption
       
Saturation
--
%
ASTM D570
Saturation, 73°F
--
%
ISO 62
Equilibrium, 50% RH
--
%
ASTM D570
Equilibrium, 73°F, 50% RH
--
%
ISO 62
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus (73°F)
psi
ISO 527-2
Tensile Strength
       
Yield, 73°F
--
psi
ASTM D638
Yield, 73°F
psi
ISO 527-2
Tensile Elongation
       
Yield, 73°F
--
%
ASTM D638
Yield, 73°F
%
ISO 527-2
Break, 73°F
--
%
ASTM D638
Nominal Tensile Strain at Break (73°F)
%
ISO 527-2
Flexural Modulus (73°F)
--
psi
ASTM D790, ISO 178
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength
      ISO 179
-22°F
--
ft·lb/in²
 
73°F
ft·lb/in²
 
Charpy Unnotched Impact Strength (73°F)
 
ISO 179
Notched Izod Impact
       
-40°F
--
ft·lb/in
ASTM D256
73°F
--
ft·lb/in
ASTM D256
73°F
--
ft·lb/in²
ISO 180
Hardness
Dry
Conditioned
Unit
Test Method
Ball Indentation Hardness
--
psi
ISO 2039-1
Thermal
Dry
Conditioned
Unit
Test Method
Deflection Temperature Under Load
       
66 psi, Unannealed
--
°F
ASTM D648
264 psi, Unannealed
--
°F
ASTM D648
264 psi, Unannealed
--
°F
ISO 75-2/A
Peak Melting Temperature
--
°F
ASTM D3418, ISO 3146
CLTE
       
Flow
--
in/in/°F
ASTM E831
Flow
--
in/in/°F
ISO 11359-2
Transverse
--
in/in/°F
ISO 11359-2
Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity
       
0.0591 in
ohm·cm
ASTM D257
--
ohm·cm
IEC 60093
Dielectric Constant (1 MHz)
 
IEC 60250
Dissipation Factor (1 MHz)
 
IEC 60250
Comparative Tracking Index
V
IEC 60112
Electric Strength
V/mil
IEC 60243-1
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating - UL (0.0591 in)
--
 
UL 94
UL
Dry
Conditioned
Unit
Test Method
RTI Str (0.0591 in)
--
°F
UL 746
RTI Imp (0.0591 in)
--
°F
UL 746
RTI Elec (0.0591 in)
--
°F
UL 746
Related Terminology
Dry
Product names can be difficult to match. You may have searched any one of these terms to find this product: Ultramid® C 3U, Ultramid C 3U, Ultramid® C , Ultramid C, UltramidC3U, UltramidC, C 3 U, C3U, C3, 3 U, 3U, Polyamide 66/6 Copolymer, Polyamide 666 Copolymer, Polyamide 66:6 Copolymer, Polyamide 66+6 Copolymer, Polyamide 66-6 Copolymer, Polyamide 66_6 Copolymer, Polyamide 66 6 Copolymer, Nylon 66/6, Nylon 666, Nylon 66:6, Nylon 66+6, Nylon 66-6, Nylon 66_6, Nylon 66 6, Polyamide, Nylon, pa666, BASF, Polyamide666Copolymer, Nylon666, Polyamide66_6Copolymer, Nylon66_6, U3, 3C
Generic Name
Dry
Generic Name may also be described by the following terms: PA666, PA66/6.
Conditioned
Generic Name may also be described by the following terms: PA666, PA66/6.
Features
Dry
Features may also be described by the following terms: Zero Halogen Content, Halogen Free, Low Phosphorus Content, Good Flow, Low Viscosity, Good Electrical Properties.
Uses
Dry
Uses may also be described by the following terms: Electrical Applications, Electronic Applications, Electrical/Electronic Applications, Electrical Sector, Electronic Insulation.
Conditioned
Product names can be difficult to match. You may have searched any one of these terms to find this product: Ultramid® C 3U, Ultramid C 3U, Ultramid® C , Ultramid C, UltramidC3U, UltramidC, C 3 U, C3U, C3, 3 U, 3U, Polyamide 66/6 Copolymer, Polyamide 666 Copolymer, Polyamide 66:6 Copolymer, Polyamide 66+6 Copolymer, Polyamide 66-6 Copolymer, Polyamide 66_6 Copolymer, Polyamide 66 6 Copolymer, Nylon 66/6, Nylon 666, Nylon 66:6, Nylon 66+6, Nylon 66-6, Nylon 66_6, Nylon 66 6, Polyamide, Nylon, pa666, BASF, Polyamide666Copolymer, Nylon666, Polyamide66_6Copolymer, Nylon66_6, U3, 3C
Injection
Dry
Unit
 
Drying Temperature
°F
 
Drying Time
hr
 
Suggested Max Moisture
%
 
Processing (Melt) Temp
°F
 
Mold Temperature
°F
 
Injection Pressure
psi
 
Injection Rate
 
 
Notes
1Typical properties: these are not to be construed as specifications.
 
IDES
Copyright © 2012 IDES
The information presented on this datasheet was acquired by IDES from the producer of the material. IDES makes substantial efforts to assure the accuracy of this data. However, IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.