IDES Prospector Already have an account? Login Here

IDES

Ultramid® 8202 HS

Polyamide 6

Supplied by BASF Corporation

The technical datasheet with complete property values for Ultramid® 8202 HS is available to members of the Prospector Plastics Database.
Register to view full datasheet.
Register to View Full Datasheet
Product Description
Ultramid 8202 HS is a heat stabilized, low viscosity, general purpose PA6 injection molding. It possesses the combination of strength and toughness and has excellent chemical and abrasion resistance. The heat stabilizer system extends the retention of properties at the more elevated temperatures. Excellent in filling thin walls or areas.
General  
Material Status 
  • Commercial: Active
Availability 
  • North America
Additive 
  • Heat Stabilizer
Features 
  • General Purpose
  • Good Abrasion Resistance
  • Good Chemical Resistance
  • Good Flow
  • Good Processability
  • Good Stiffness
  • Good Toughness
  • Heat Stabilized
  • High Strength
  • Homopolymer
  • Low Viscosity
Uses 
  • Bearings
  • Fasteners
  • Fittings
  • Furniture
  • Gears
  • Handles
  • Thin-walled Parts
Agency Ratings 
RoHS Compliance 
Automotive Specifications 
Appearance 
  • Colors Available
  • Natural Color
 
Forms 
  • Pellets
Processing Method 
  • Injection Molding
Multi-Point Data 
  • Isothermal Stress vs. Strain (ISO 11403-1)
  • Secant Modulus vs. Strain (ISO 11403-1)
  • Shear Modulus vs. Temperature (ISO 11403-1)
  • Viscosity vs. Shear Rate (ISO 11403-2)
 
Physical
Dry
Conditioned
Unit
Test Method
Specific Gravity        
--
--
 
ASTM D792
--
--
lb/in³
ISO 1183 2
Molding Shrinkage - Flow (0.125 in)
--
in/in
ASTM D955
Water Absorption        
24 hr
--
%
ASTM D570
73°F, 24 hr
--
%
ISO 62
Saturation
--
%
ASTM D570, ISO 62 2
Equilibrium, 50% RH
--
%
ASTM D570
Equilibrium
--
%
ISO 62 2
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus        
176°F
psi
ISO 527-2
250°F
psi
ISO 527-2
--
psi
ISO 527-2 2
Tensile Strength        
Yield, -40°F
psi
ASTM D638, ISO 527-2
Yield, 73°F
psi
ASTM D638
Yield, 176°F
psi
ASTM D638, ISO 527-2
Yield, 250°F
psi
ASTM D638, ISO 527-2
Yield
psi
ISO 527-2 2
Break, 73°F
psi
ASTM D638
Tensile Elongation        
Yield, 73°F
%
ASTM D638
Yield, 176°F
%
ASTM D638
Yield, 250°F
%
ASTM D638
Yield
%
ISO 527-2 2
Break, 73°F
%
ASTM D638
Nominal strain at break
%
ISO 527-2 2
Flexural Modulus        
-40°F
psi
ASTM D790
73°F
psi
ASTM D790
149°F
--
psi
ASTM D790
194°F
--
psi
ASTM D790
250°F
--
psi
ASTM D790
73°F
psi
ISO 178
Flexural Strength        
-40°F
psi
ASTM D790
73°F
psi
ASTM D790
149°F
--
psi
ASTM D790
194°F
--
psi
ASTM D790
250°F
--
psi
ASTM D790
73°F
psi
ISO 178
Impact
Dry
Conditioned
Unit
Test Method
Charpy notched impact strength (73°F)
--
ft·lb/in²
ISO 179/1eA 2
Charpy Unnotched Impact Strength       ISO 179
-22°F
--
ft·lb/in²
 
73°F
--
 
 
Notched Izod Impact       ASTM D256
-40°F
ft·lb/in
 
73°F
 
 
Drop Impact Resistance (73°F)
ft·lb
Internal Method
Hardness
Dry
Conditioned
Unit
Test Method
Rockwell Hardness (R-Scale)
--
 
ASTM D785
Thermal
Dry
Conditioned
Unit
Test Method
Deflection Temperature Under Load        
66 psi, Unannealed
--
°F
ASTM D648
264 psi, Unannealed
--
°F
ASTM D648
264 psi
--
°F
ISO 75-2 2
Melting Temperature
--
°F
ASTM D3418, ISO 3146
CLTE - Flow
--
in/in/°F
ASTM E831
Electrical
Dry
Conditioned
Unit
Test Method
Volume Resistivity        
0.0591 in
--
ohm·cm
ASTM D257
--
--
ohm·in
IEC 60093 2
Dielectric Strength        
0.0591 in 3
--
V/mil
ASTM D149
--
--
V/mil
IEC 60243-1 2
Comparative tracking index
--
 
IEC 60112 2
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating - UL (0.0591 in)
--
 
UL 94
UL
Dry
Conditioned
Unit
Test Method
RTI Str (0.0591 in)
--
°F
UL 746
RTI Imp (0.0591 in)
--
°F
UL 746
RTI Elec (0.0591 in)
--
°F
UL 746
Related Terminology
Dry
Product names can be difficult to match. You may have searched any one of these terms to find this product: Ultramid® 8202 HS, Ultramid 8202 HS, Ultramid® , Ultramid, Ultramid8202HS, 8202 HS, 8202HS, Polyamide 6, Nylon 6, Polyamide, Nylon, pa6, BASF, Polyamide6, Nylon6, HS8202
Generic Name
Dry
Generic Name may also be described by the following terms: PA6.
Conditioned
Generic Name may also be described by the following terms: PA6.
Features
Dry
Features may also be described by the following terms: Good Abrasion Resistance, Abrasion Resistant, Heat Stabilized, Heat-ageing Stabilized, Heat Ageing Stabilized, Heat-aging Stabilized, Heat Aging Stabilized, Good Chemical Resistance, Chemical Resistant, Low Viscosity, Good Toughness, Tough, Good Stiffness, High Strength, Good Flow, Good Processability, Easy Processing.
Uses
Dry
Uses may also be described by the following terms: Thin-walled Parts, Thin Walled Parts, Thin-wall Parts, Thin wall Parts, Thinwall Parts.
Automotive Specifications
Dry
This plastic material has approval for 9 automotive specifications from the following agencies (the number in parentheses shows the number of specifications for that agency): FORD (2), ASTM (1), CHRYSLER (4), GM (2).
Agency Ratings
Dry
This plastic material has 1 certifications from the following agencies (the number in parentheses shows the number of certifications for that agency): ULC (1).
Conditioned
Product names can be difficult to match. You may have searched any one of these terms to find this product: Ultramid® 8202 HS, Ultramid 8202 HS, Ultramid® , Ultramid, Ultramid8202HS, 8202 HS, 8202HS, Polyamide 6, Nylon 6, Polyamide, Nylon, pa6, BASF, Polyamide6, Nylon6, HS8202
Injection
Dry
Unit
 
Drying Temperature
°F
 
Drying Time
hr
 
Suggested Max Moisture
%
 
Processing (Melt) Temp
°F
 
Mold Temperature
°F
 
Injection Pressure
psi
 
Injection Rate
 
 
Notes
1Typical properties: these are not to be construed as specifications.
2Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted.
3Method A (Short-Time)
 
IDES
Copyright © 2012 IDES
The information presented on this datasheet was acquired by IDES from the producer of the material. IDES makes substantial efforts to assure the accuracy of this data. However, IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.