Tensile Strength @ Break, ASTM D 882, MD & TD: 30000 - 42000 psi Elongation @ Break, ASTM 882, MD & TD: 70 - 110% Secant Modulus, ASTM D 882, MD & TD: 350000 - 475000 psi Elmendorf Tear Str, ASTM D 1922, MD & TD: 15 - 19 g/mil Graves Tear (initial), ASTM D 1004: 1100 - 1400 g/mil Gloss (20°), ASTM D 2457: 75 - 85 Coefficient of Friction, ASTM D 1894: 0.65 - 0.90 vs Itself-Dynamic Coefficient of Friction, ASTM D 1894: 0.24 - 0.30 vs Metal-Dynamic Oxygen Permeability, ASTM D 3985, 73°F/0% RH: .52 cc/100 in²/day
The value listed as Mold Shrink, Linear-Flow, ASTM D 955, was tested in accordance with ASTM D 1204. The value listed as Mold Shrink, Linear-Trans, ASTM D 955, was tested in accordance with ASTM D 1204. The value listed as Water Vapor Transmission , ASTM E 96, was tested in accordance with ASTM F 1249.
|
|
Product names can be difficult to match. You may have searched any one of these terms to find this product: OxyShield® 2545, OxyShield 2545, OxyShield® , OxyShield, OxyShield2545, 2545, Polyamide 6, Nylon 6, Polyamide, Nylon, pa6, Honeywell, Polyamide6, Nylon6
|