IDES Prospector Already have an account? Login Here

IDES

CALIBRE™ 2061-15

Polycarbonate Resin

Supplied by Styron LLC

The technical datasheet with complete property values for CALIBRE™ 2061-15 is available to members of the Prospector Plastics Database.
Register to view full datasheet.
Register to View Full Datasheet
Product Description
CALIBRE™ 2061-15 resin is suitable for steam and ethylene oxide sterilization required by the health care industry. CALIBRE 2061-15 provides exceptional clarity, heat resistance, impact strength, processability, and has low contamination levels. CALIBRE 2061-15 resin is compliant with ISO 10993 (Biological Evaluation of Medical Devices) and is suitable for use in approved medical applications. This product contains mold release.

Main Characteristics:
  • ISO 10993

Applications:
  • Medical applications
General  
Material Status 
  • Commercial: Active
Availability 
  • Europe
  • Latin America
  • North America
Additive 
  • Mold Release
Agency Ratings 
  •  1
Forms 
  • Pellets
Processing Method 
  • Injection Molding
Multi-Point Data 
  • Tensile Stress vs. Strain (ASTM D638)
  • Viscosity vs. Shear Rate (ASTM D3835)
 
Physical
Nominal Value
Unit
Test Method
Specific Gravity
     
--
 
ASTM D792
--
g/cm³
ISO 1183/A
--
lb/in³
ISO 1183 3
Melt Mass-Flow Rate (MFR) (300°C/1.2 kg)
g/10 min
ASTM D1238, ISO 1133
Melt volume-flow rate (300°C/1.2 kg)
in³/10min
ISO 1133 3
Molding Shrinkage - Flow
     
--
in/in
ASTM D955
--
%
ISO 294-4
Water Absorption
    ASTM D570, ISO 62
73°F, 24 hr
%
 
Equilibrium, 73°F, 50% RH
%
 
Mechanical
Nominal Value
Unit
Test Method
Tensile Modulus
     
-- 4
psi
ASTM D638
--
psi
ISO 527-2/50, ISO 527-2 3
Tensile Strength
     
Yield 4
psi
ASTM D638
Yield
psi
ISO 527-2/50
Yield
psi
ISO 527-2 3
Break 4
psi
ASTM D638
Break
psi
ISO 527-2/50
Tensile Elongation
     
Yield 4
%
ASTM D638
Yield
%
ISO 527-2/50, ISO 527-2 3
Break 4
%
ASTM D638
Break
%
ISO 527-2/50
Nominal strain at break
%
ISO 527-2 3
Flexural Modulus
     
-- 5
psi
ASTM D790
-- 6
psi
ISO 178
Flexural Strength
     
-- 5
psi
ASTM D790
-- 6
psi
ISO 178
Impact
Nominal Value
Unit
Test Method
Charpy Notched Impact Strength
     
73°F
ft·lb/in²
ISO 179/1eA
-22°F
ft·lb/in²
ISO 179/1eA 3
73°F
ft·lb/in²
ISO 179/1eA 3
Charpy impact strength
    ISO 179/1eU 3
-22°F
 
 
73°F
 
 
Notched Izod Impact
     
73°F
ft·lb/in
ASTM D256
73°F
ft·lb/in²
ISO 180/A
Unnotched Izod Impact (73°F)
 
ASTM D256, ISO 180
Instrumented Dart Impact 7 (73°F, Total Energy)
in·lb
ASTM D3763
Tensile Impact Strength
ft·lb/in²
ASTM D1822
Hardness
Nominal Value
Unit
Test Method
Rockwell Hardness
    ASTM D785
M-Scale
 
 
R-Scale
 
 
Thermal
Nominal Value
Unit
Test Method
Deflection Temperature Under Load
     
66 psi, Annealed
°F
ASTM D648, ISO 75-2/B
66 psi
°F
ISO 75-2 3
264 psi, Unannealed
°F
ASTM D648
264 psi, Unannealed
°F
ISO 75-2/A
264 psi, Annealed
°F
ASTM D648, ISO 75-2/A
264 psi
°F
ISO 75-2 3
Vicat Softening Temperature
     
--
°F
ASTM D1525 8
--
°F
ISO 306/B50
50°C/h, B (50N)
°F
ISO 306 3
CLTE - Flow
     
-40 to 180°F
in/in/°F
ASTM D696
--
in/in/°F
ISO 11359-2 3
Electrical
Nominal Value
Unit
Test Method
Volume Resistivity
     
--
ohm·cm
ASTM D257
--
ohm·in
IEC 60093 3
Dielectric Strength
     
--
V/mil
ASTM D149
--
V/mil
IEC 60243-1
Dielectric Constant
     
60 Hz
 
ASTM D150
1 MHz
 
ASTM D150, IEC 60250 3
100 Hz
 
IEC 60250 3
Dissipation Factor
     
50 Hz
 
ASTM D150
1 MHz
 
ASTM D150, IEC 60250 3
100 Hz
 
IEC 60250 3
Flammability
Nominal Value
Unit
Test Method
Flame Rating - UL 9 (0.0591 in)
 
UL 94
Oxygen index
%
ISO 4589-2 3
Optical
Nominal Value
Unit
Test Method
Refractive Index
 
ASTM D542, ISO 489
Transmittance 10
%
ASTM D1003
Haze 10
%
ASTM D1003
Related Terminology
Product names can be difficult to match. You may have searched any one of these terms to find this product: CALIBRE™ 2061-15, CALIBRE 206115, CALIBRE™ , CALIBRE, CALIBRE206115, 2061, 2061-15, 206115, 2061:15, 2061/15, 2061+15, 2061_15, 2061 15, Polycarbonate, PC, Styron, 152061
Agency Ratings
This plastic material has 1 certifications from the following agencies (the number in parentheses shows the number of certifications for that agency): ISO (1).
Notes
1Biocompatibility testing following ISO Guidelines 10993 has been completed on select classic resins in this series. Please consult Styron for details. ISO guidelines include a sensitization test.
2Typical properties: these are not to be construed as specifications.
3Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted.
42.0 in/min
5Method I (3 point load), 0.079 in/min
60.079 in/min
711.1 ft/sec
8Rate A (50°C/h), Loading 2 (50 N)
9This rating not intended to reflect hazards presented by this or any other material under actual fire conditions.
10Measured at 3.2mm thickness on un-colored resin.
 
IDES
Copyright © 2012 IDES
The information presented on this datasheet was acquired by IDES from the producer of the material. IDES makes substantial efforts to assure the accuracy of this data. However, IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.