IDES Prospector Already have an account? Login Here

IDES

Zytel® HTN 51G45HSL NC010

HIGH PERFORMANCE POLYAMIDE RESIN

Glass Fiber Reinforcement, 45%

Supplied by DuPont Performance Polymers

The technical datasheet with complete property values for Zytel® HTN 51G45HSL NC010 is available to members of the Prospector Plastics Database.
Register to view full datasheet.
Register to View Full Datasheet
Product Description
Zytel® HTN51G45HSL NC010 is a 45% glass reinforced, heat stabilized, lubricated high performance polyamide resin. It is also a PPA resin.
General  
Material Status 
  • Commercial: Active
Availability 
  • Asia Pacific
  • Europe
  • North America
Filler / Reinforcement 
  • Glass Fiber Reinforcement, 45% Filler by Weight
Additive 
  • Heat Stabilizer
  • Lubricant
  • Mold Release
Features 
  • Good Dimensional Stability
  • Good Electrical Properties
  • Good Heat Aging Resistance
  • Good Stiffness
  • Heat Stabilized
  • Low to No Water Absorption
  • Ultrasonic Weldable
Uses 
  • Automotive Applications
  • Electric Motor Housings
  • Electrical Housing
  • Electrical/Electronic Applications
 
RoHS Compliance 
Automotive Specifications 
  •  1
Appearance 
  • Natural Color
Processing Method 
  • Injection Molding
Multi-Point Data 
  • Isothermal Stress vs. Strain (ISO 11403-1)
Part Marking Code (ISO 11469)
  • >PA6T/XT-GF45<
Resin ID (ISO 1043)
  • PA6T/XT-GF45
Part Marking Code (SAE J1344)
Physical
Dry
Conditioned
Unit
Test Method
Specific Gravity        
--
--
 
ASTM D792
--
--
g/cm³
ISO 1183
Molding Shrinkage        
Flow: 0.0630 in
--
in/in
Internal Method
Flow: 0.126 in
--
in/in
Internal Method
Across Flow: 0.0630 in
--
in/in
Internal Method
Across Flow: 0.126 in
--
in/in
Internal Method
Across Flow: 0.0787 in
--
%
ISO 294-4
Flow: 0.0787 in
--
%
ISO 294-4
Water Absorption        
73°F, 24 hr
--
%
ASTM D570
73°F, 24 hr, 0.0787 in
--
%
ISO 62
Saturation, 73°F
--
%
ASTM D570
Saturation, 73°F, 0.0787 in
--
%
ISO 62
Equilibrium, 73°F, 0.0787 in, 50% RH
--
%
ISO 62
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus        
-40°F
--
psi
ASTM D638
73°F
--
psi
ASTM D638
212°F
--
psi
ASTM D638
302°F
--
psi
ASTM D638
347°F
--
psi
ASTM D638
73°F
psi
ISO 527-2
Tensile Stress        
Break, 73°F
psi
ISO 527-2
-40°F
--
psi
ASTM D638
73°F
psi
ASTM D638
212°F
--
psi
ASTM D638
302°F
--
psi
ASTM D638
347°F
--
psi
ASTM D638
Tensile Elongation        
Break, -40°F
--
%
ASTM D638
Break, 73°F
%
ASTM D638
Break, 212°F
--
%
ASTM D638
Break, 302°F
--
%
ASTM D638
Break, 347°F
--
%
ASTM D638
Break, 73°F
%
ISO 527-2
Tensile Creep Modulus       ISO 899-1
1 hr
--
psi
 
1000 hr
--
psi
 
Flexural Modulus        
-40°F
--
psi
ASTM D790
73°F
--
psi
ASTM D790
212°F
--
psi
ASTM D790
302°F
--
psi
ASTM D790
347°F
--
psi
ASTM D790
392°F
--
psi
ASTM D790
73°F
psi
ISO 178
Flexural Strength       ASTM D790
-40°F
psi
 
73°F
psi
 
212°F
psi
 
5.0% Strain, 302°F
psi
 
5.0% Strain, 347°F
psi
 
5.0% Strain, 392°F
psi
 
Compressive Strength        
302°F
--
psi
ASTM D695
347°F
--
psi
ASTM D695
392°F
--
psi
ASTM D695
-40°F
--
psi
ASTM D695
73°F
--
psi
ASTM D695
212°F
--
psi
ASTM D695
73°F
--
psi
ISO 604
Shear Strength (73°F)
psi
ASTM D732
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength       ISO 179/1eA
-40°F
--
ft·lb/in²
 
-22°F
--
ft·lb/in²
 
73°F
ft·lb/in²
 
Charpy Unnotched Impact Strength       ISO 179/1eU
-22°F
--
ft·lb/in²
 
73°F
ft·lb/in²
 
Notched Izod Impact        
-40°F
ft·lb/in
ASTM D256
73°F
ft·lb/in
ASTM D256
-40°F
--
ft·lb/in²
ISO 180/1A
-22°F
--
ft·lb/in²
ISO 180/1A
73°F
ft·lb/in²
ISO 180/1A
Unnotched Izod Impact        
-40°F
ft·lb/in
ASTM D4812
73°F
ft·lb/in
ASTM D4812
73°F
--
ft·lb/in²
ISO 180/1U
Hardness
Dry
Conditioned
Unit
Test Method
Rockwell Hardness       ASTM D785, ISO 2039-2
M-Scale
--
 
 
R-Scale
--
 
 
Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature        
66 psi, Unannealed
--
°F
ISO 75-2/B
264 psi, Unannealed
--
°F
ASTM D648
264 psi, Unannealed
--
°F
ISO 75-2/A
Glass Transition Temperature (DSC)
°F
DSC
Melting Temperature 3
--
°F
ISO 11357-3, ASTM D3418
CLTE        
Flow: -40 to 73°F
--
in/in/°F
ASTM E831
Flow: 73 to 131°F
--
in/in/°F
ASTM E831, ISO 11359-2
Flow: 131 to 257°F
--
in/in/°F
ASTM E831, ISO 11359-2
Flow: -40 to 73°F
--
in/in/°F
ISO 11359-2
Flow: 131 to 320°F
--
in/in/°F
ISO 11359-2
Transverse: -40 to 73°F
--
in/in/°F
ASTM E831
Transverse: 73 to 131°F
--
in/in/°F
ASTM E831
Transverse: 131 to 320°F
--
in/in/°F
ASTM E831
Transverse: -40 to 73°F
--
in/in/°F
ISO 11359-2
Transverse: 73 to 131°F
--
in/in/°F
ISO 11359-2
Transverse: 131 to 257°F
--
in/in/°F
ISO 11359-2
Electrical
Dry
Conditioned
Unit
Test Method
Surface Resistivity        
--
--
ohms
ASTM D257
--
ohms
IEC 60093
Volume Resistivity        
73°F
--
ohm·cm
ASTM D257
--
ohm·cm
IEC 60093
Dielectric Strength        
73°F, 0.0630 in 4
--
V/mil
ASTM D149
212°F, 0.0630 in 4
--
V/mil
ASTM D149
302°F, 0.0630 in 4
--
V/mil
ASTM D149
347°F, 0.0630 in 4
--
V/mil
ASTM D149
392°F, 0.0630 in 4
--
V/mil
ASTM D149
73°F, 0.0394 in
V/mil
IEC 60243-1
73°F, 0.0787 in
--
V/mil
IEC 60243-1
Dielectric Constant        
73°F, 1 kHz
--
 
ASTM D150
73°F, 1 MHz
--
 
ASTM D150
212°F, 1 kHz
--
 
ASTM D150
212°F, 1 MHz
--
 
ASTM D150
302°F, 1 kHz
--
 
ASTM D150
302°F, 1 MHz
--
 
ASTM D150
347°F, 1 kHz
--
 
ASTM D150
347°F, 1 MHz
--
 
ASTM D150
392°F, 1 kHz
--
 
ASTM D150
392°F, 1 MHz
--
 
ASTM D150
73°F, 100 Hz
--
 
IEC 60250
73°F, 1 MHz
--
 
IEC 60250
Dissipation Factor        
73°F, 1 kHz
--
 
ASTM D150
73°F, 1 MHz
--
 
ASTM D150
212°F, 1 kHz
--
 
ASTM D150
212°F, 1 MHz
--
 
ASTM D150
302°F, 1 kHz
--
 
ASTM D150
302°F, 1 MHz
--
 
ASTM D150
347°F, 1 kHz
--
 
ASTM D150
347°F, 1 MHz
--
 
ASTM D150
392°F, 1 kHz
--
 
ASTM D150
392°F, 1 MHz
--
 
ASTM D150
73°F, 100 Hz
--
 
IEC 60250
73°F, 1 MHz
--
 
IEC 60250
Comparative Tracking Index        
--
V
IEC 60112
--
--
V
ASTM D3638
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating - UL       UL 94
0.0335 in
--
 
 
0.0591 in
--
 
 
0.118 in
--
 
 
Flammability Classification       IEC 60695-11-10, -20
0.0335 in
--
 
 
0.0591 in
--
 
 
0.118 in
--
 
 
Oxygen Index
--
%
ASTM D2863, ISO 4589-2
UL
Dry
Conditioned
Unit
Test Method
RTI Str       UL 746
0.0335 in
--
°F
 
0.0591 in
--
°F
 
0.118 in
--
°F
 
RTI Imp       UL 746
0.0335 in
--
°F
 
0.0591 in
--
°F
 
0.118 in
--
°F
 
RTI Elec       UL 746
0.0335 in
--
°F
 
0.0591 in
--
°F
 
0.118 in
--
°F
 
Comparative Tracking Index (CTI)
--
V
UL 746
Related Terminology
Dry
Product names can be difficult to match. You may have searched any one of these terms to find this product: Zytel® HTN 51G45HSL NC010, Zytel HTN 51G45HSL NC010, Zytel® HTN , Zytel HTN, ZytelHTN51G45HSLNC010, ZytelHTN, HTN 51 G 45 HSL NC 010, HTN51G45HSL NC010, HTN51, HTN, 51 G 45 HSL NC 010, HTN51G45HSLNC010, 51G45HSL NC010, 51G, G45, 45HSL, HSLNC, NC010, 51G45HSLNC010, Polyphthalamide, PPA, Polyamide, Nylon, DuPont, G51, 51HTN
Features
Dry
Features may also be described by the following terms: Heat Stabilized, Heat-ageing Stabilized, Heat Ageing Stabilized, Heat-aging Stabilized, Heat Aging Stabilized, Low Water Absorption, Low Moisture Absorption, Water Resistant, Moisure Resistant, Good Electrical Properties, Good Dimensional Stability, Dimensionally Stable, Good Heat Aging Resistance, Good Stiffness, Ultrasonic Weldable.
Uses
Dry
Uses may also be described by the following terms: Electrical Applications, Electronic Applications, Electrical/Electronic Applications, Electrical Sector, Electrical Housings, Electrical Housing, Automotive Applications, Automotive Sector, Electric Motor Housings, Electric Motor Housing.
Automotive Specifications
Dry
This plastic material has approval for 1 automotive specifications from the following agencies (the number in parentheses shows the number of specifications for that agency): GM (1).
Conditioned
Product names can be difficult to match. You may have searched any one of these terms to find this product: Zytel® HTN 51G45HSL NC010, Zytel HTN 51G45HSL NC010, Zytel® HTN , Zytel HTN, ZytelHTN51G45HSLNC010, ZytelHTN, HTN 51 G 45 HSL NC 010, HTN51G45HSL NC010, HTN51, HTN, 51 G 45 HSL NC 010, HTN51G45HSLNC010, 51G45HSL NC010, 51G, G45, 45HSL, HSLNC, NC010, 51G45HSLNC010, Polyphthalamide, PPA, Polyamide, Nylon, DuPont, G51, 51HTN
Injection
Dry
Unit
 
Drying Temperature
°F
 
Drying Time
hr
 
Suggested Max Moisture
%
 
Processing (Melt) Temp
°F
 
Melt Temperature, Optimum
°F
 
Mold Temperature
°F
 
Mold Temperature, Optimum
°F
 
Drying Recommended
 
 
Notes
1This specification is applicable for the Americas region.
2Typical properties: these are not to be construed as specifications.
310°C/min, First Heat
4Method A (Short-Time)
 
IDES
Copyright © 2012 IDES
The information presented on this datasheet was acquired by IDES from the producer of the material. IDES makes substantial efforts to assure the accuracy of this data. However, IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.