IDES Prospector Already have an account? Login Here

IDES

TECHNYL® A 20H1 V25

Polyamide 66

Glass Fiber Reinforcement, 25%

Supplied by Rhodia Engineering Plastics SA

The technical datasheet with complete property values for TECHNYL® A 20H1 V25 is available to members of the Prospector Plastics Database.
Register to view full datasheet.
Register to View Full Datasheet
Product Description
Flame retardant polyamide 66, reinforced with 25% of glass fibre, heat stabilised, for injection moulding.

This phosphorus flame retardant grade, UL 94 V0 (0.8 mm, offers excellent filling qualities and with good mechanical properties. This grade is stabilised to offer a very low migration and corrosion of metallic contacts.

It is particularly suitable for moulding insulating parts for electrical devices:
  • connectors,
  • contactors,
  • bobbins coil formers,
  • thin parts under stress.
General  
Material Status 
  • Commercial: Active
Availability 
  • Africa & Middle East
  • Asia Pacific
  • Europe
  • Latin America
  • North America
  • South America
Filler / Reinforcement 
  • Glass Fiber Reinforcement, 25% Filler by Weight
Additive 
  • Flame Retardant
  • Heat Stabilizer
 
Features 
  • Flame Retardant
  • Heat Stabilized
 
Uses 
  • Connectors
  • Thin-walled Parts
 
Appearance 
  • Black
Forms 
  • Pellets
Processing Method 
  • Injection Molding
Multi-Point Data 
  • Isothermal Stress vs. Strain (ISO 11403-1)
  • Secant Modulus vs. Strain (ISO 11403-1)
 
Part Marking Code (ISO 11469)
  • >PA66-GF25 FR(52)<
Physical
Dry
Conditioned
Unit
Test Method
Density
       
--
--
g/cm³
ISO 1183
--
--
lb/in³
ISO 1183 2
Water Absorption (73°F, 24 hr)
--
%
ISO 62
Viscosity number
--
cm³/g
ISO 307, 1157, 1628 2
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
psi
ISO 527-2/1A 2, ISO 527-2 2
Tensile Stress (Break)
psi
ISO 527-2/1A 2, ISO 527-2 2
Tensile Strain (Break)
%
ISO 527-2/1A 2, ISO 527-2 2
Flexural Modulus
psi
ISO 178
Flexural Strength
psi
ISO 178
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength
       
--
ft·lb/in²
ISO 179/1eA
73°F
ft·lb/in²
ISO 179/1eA 2
Charpy Unnotched Impact Strength
       
--
ft·lb/in²
ISO 179/1eU
73°F
ft·lb/in²
ISO 179/1eU 2
Notched Izod Impact Strength
ft·lb/in²
ISO 180/1A
Thermal
Dry
Conditioned
Unit
Test Method
Deflection Temperature Under Load
       
66 psi
--
°F
ISO 75-2 2
264 psi, Unannealed
--
°F
ISO 75-2/Af
264 psi
--
°F
ISO 75-2 2
Melting Temperature (DSC)
       
--
--
°F
ISO 3146
-- 3
--
°F
ISO 11357-3 2
CLTE
       
Flow
--
in/in/°F
ISO 11359-2 2
Transverse: 73 to 185°F
--
in/in/°F
ISO 11359-2
Electrical
Dry
Conditioned
Unit
Test Method
Surface Resistivity
       
--
ohm
IEC 60093
--
--
ohm
IEC 60093 2
Volume Resistivity
       
--
ohm·cm
IEC 60093
--
ohm·in
IEC 60093 2
Relative Permittivity (1 MHz)
 
IEC 60250 2
Dissipation Factor
       
--
 
IEC 60250
1 MHz
 
IEC 60250 2
Comparative Tracking Index
       
Solution A
V
IEC 60112
--
--
 
IEC 60112 2
Electric Strength
V/mil
IEC 60243-1
Flammability
Dry
Conditioned
Unit
Test Method
Flame Rating - UL
      UL 94
0.0315 in
--
 
 
0.0630 in
--
 
 
0.126 in
--
 
 
Burning Behav. at 1.6mm nom. thickn. (0.06 in)
--
 
ISO 1210 2
Burning Behav. at thickness h (0.0315 in)
--
 
ISO 1210 2
Glow Wire Flammability Index
      IEC 60695-2-12
0.0315 in
--
°F
 
0.0630 in
--
°F
 
Oxygen Index
--
%
ISO 4589-2
Additional Information
Dry
The value listed as Melting Temperature (DSC), ISO 3146, was tested in accordance with ISO 11357.
Molding Shrinkage, Rhodia Method, Isotropy: 0.55
Molding Shrinkage, Rhodia Method, Normal/Perpendicular: 0.9%
Molding Shrinkage, Rhodia Method, Parallel: 0.5%
Related Terminology
Dry
Product names can be difficult to match. You may have searched any one of these terms to find this product: TECHNYL® A 20H1 V25, TECHNYL A 20H1 V25, TECHNYL® A , TECHNYL A, TECHNYLA20H1V25, TECHNYLA, A 20 H 1 V 25, A20H1 V25, A20, 20 H 1 V 25, A20H1V25, 20H1 V25, 20H, H1, 1V, V25, 20H1V25, Polyamide 66, Nylon 66, Polyamide, Nylon, pa66, Rhodia, Polyamide66, Nylon66, H20, 20A
Generic Name
Dry
Generic Name may also be described by the following terms: PA66.
Conditioned
Generic Name may also be described by the following terms: PA66.
Features
Dry
Features may also be described by the following terms: Heat Stabilized, Heat-ageing Stabilized, Heat Ageing Stabilized, Heat-aging Stabilized, Heat Aging Stabilized.
Uses
Dry
Uses may also be described by the following terms: Thin-walled Parts, Thin Walled Parts, Thin-wall Parts, Thin wall Parts, Thinwall Parts.
Conditioned
Product names can be difficult to match. You may have searched any one of these terms to find this product: TECHNYL® A 20H1 V25, TECHNYL A 20H1 V25, TECHNYL® A , TECHNYL A, TECHNYLA20H1V25, TECHNYLA, A 20 H 1 V 25, A20H1 V25, A20, 20 H 1 V 25, A20H1V25, 20H1 V25, 20H, H1, 1V, V25, 20H1V25, Polyamide 66, Nylon 66, Polyamide, Nylon, pa66, Rhodia, Polyamide66, Nylon66, H20, 20A
Injection
Dry
Unit
 
Drying Temperature
°F
 
Suggested Max Moisture
%
 
Rear Temperature
°F
 
Middle Temperature
°F
 
Front Temperature
°F
 
Mold Temperature
°F
 
Notes
1Typical properties: these are not to be construed as specifications.
2Tested in accordance with ISO 10350. 23°C/50%r.h. unless otherwise noted.
318 °F/min
 
IDES
Copyright © 2012 IDES
The information presented on this datasheet was acquired by IDES from the producer of the material. IDES makes substantial efforts to assure the accuracy of this data. However, IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.