IDES Prospector Already have an account? Login Here

IDES

Grivory® GV-2H

Polyamide 66 + PA 6I/X

Glass Fiber Reinforcement, 20%

Supplied by EMS-GRIVORY

The technical datasheet with complete property values for Grivory® GV-2H is available to members of the Prospector Plastics Database.
Register to view full datasheet.
Register to View Full Datasheet
General  
Material Status 
  • Commercial: Active
Availability 
  • Africa & Middle East
  • Asia Pacific
  • Central America
  • Europe
  • North America
  • South America
Filler / Reinforcement 
  • Glass Fiber Reinforcement, 20% Filler by Weight
Features 
  • Aromatic
Uses 
  • Appliance Components
  • Automotive Applications
  • Automotive Exterior Parts
  • Automotive Interior Parts
  • Electrical/Electronic Applications
  • Engineering Parts
  • Household Goods
  • Hydraulic Applications
  • Industrial Applications
  • Pneumatic Applications
  • Power/Other Tools
  • Sporting Goods
Agency Ratings 
RoHS Compliance 
Automotive Specifications 
Processing Method 
  • Injection Molding
Multi-Point Data 
  • Isothermal Stress vs. Strain (ISO 11403-1)
  • Secant Modulus vs. Strain (ISO 11403-1)
  • Shear Modulus vs. Temperature (ISO 11403-1)
  • Specific Volume vs Temperature (ISO 11403-2)
  • Viscosity vs. Shear Rate (ISO 11403-2)
Physical
Dry
Conditioned
Unit
Test Method
Density
--
g/cm³
ISO 1183
Molding Shrinkage
      ISO 294-4
Across Flow
--
%
 
Flow
--
%
 
Water Absorption
      ISO 62
Saturation, 73°F
--
%
 
Equilibrium, 73°F, 50% RH
--
%
 
Mechanical
Dry
Conditioned
Unit
Test Method
Tensile Modulus
psi
ISO 527-2
Tensile Stress (Break)
psi
ISO 527-2
Tensile Strain (Break)
%
ISO 527-2
Impact
Dry
Conditioned
Unit
Test Method
Charpy Notched Impact Strength
      ISO 179/1eA
-22°F
ft·lb/in²
 
73°F
ft·lb/in²
 
Charpy Unnotched Impact Strength
      ISO 179/1eU
-22°F
ft·lb/in²
 
73°F
ft·lb/in²
 
Hardness
Dry
Conditioned
Unit
Test Method
Ball Indentation Hardness
psi
ISO 2039-1
Thermal
Dry
Conditioned
Unit
Test Method
Heat Deflection Temperature
       
264 psi, Unannealed
--
°F
ISO 75-2/A
1160 psi, Unannealed
--
°F
ISO 75-2/C
Max. Continuous Use Temperature
      Internal Method
-- 2
--
°F
 
-- 3
--
°F
 
Melting Temperature 4
--
°F
ISO 11357-3
CLTE
      ISO 11359-2
Flow
--
in/in/°F
 
Transverse
--
in/in/°F
 
Electrical
Dry
Conditioned
Unit
Test Method
Surface Resistivity
--
ohms
IEC 60093
Volume Resistivity
ohm·cm
IEC 60093
Comparative Tracking Index
--
V
IEC 60112
Electric Strength
V/mil
IEC 60243-1
Flammability
Dry
Conditioned
Unit
Test Method
Flammability Classification (0.0315 in)
--
 
IEC 60695-11-10, -20
Additional Information
Dry
Conditioned
Unit
Test Method
Product Description
--
 
ISO 1874
Related Terminology
Dry
This supplier and product may also be known by these terms: Gryvory

Product names can be difficult to match. You may have searched any one of these terms to find this product: Grivory® GV-2H, Grivory GV2H, Grivory® , Grivory, GrivoryGV2H, GV, GV 2 H, GV-2H, GV2H, GV:2H, GV/2H, GV+2H, GV_2H, GV 2H, GV2, 2H, Polyamide 66 + PA 6I/X, Polyamide 66 PA 6IX, Polyamide 66 + PA 6I:X, Polyamide 66 + PA 6I+X, Polyamide 66 + PA 6I-X, Polyamide 66 + PA 6I_X, Polyamide 66 + PA 6I X, Polyamide 66 : PA 6I/X, Polyamide 66 / PA 6I/X, Polyamide 66 - PA 6I/X, Polyamide 66 _ PA 6I/X, Polyamide 66 PA 6I/X, Nylon 66+Nylon 6I/X, Nylon 66Nylon 6IX, Nylon 66+Nylon 6I:X, Nylon 66+Nylon 6I+X, Nylon 66+Nylon 6I-X, Nylon 66+Nylon 6I_X, Nylon 66+Nylon 6I X, Nylon 66:Nylon 6I/X, Nylon 66/Nylon 6I/X, Nylon 66-Nylon 6I/X, Nylon 66_Nylon 6I/X, Nylon 66 Nylon 6I/X, Polyamide, Nylon, EMS-Grivory, Polyamide66PA6IX, Polyamide 66 PA 6I_X, Polyamide 66 PA 6I X, Polyamide 66 _ PA 6IX, Nylon66Nylon6IX, Nylon 66Nylon 6I_X, Nylon 66Nylon 6I X, Nylon 66_Nylon 6IX, Nylon 66 Nylon 6IX, Polyamide66PA6I_X, Polyamide66_PA6IX, Nylon66Nylon6I_X, Nylon66_Nylon6IX, 2GV
Generic Name
Dry
Generic Name may also be described by the following terms: PA66+PA6I/X.
Conditioned
Generic Name may also be described by the following terms: PA66+PA6I/X.
Uses
Dry
Uses may also be described by the following terms: Household Goods, Housewares, Appliance Components, Appliance Parts, Power Tools, Tools, Automotive Applications, Automotive Sector, Engineering Parts, Electrical Applications, Electronic Applications, Electrical/Electronic Applications, Electrical Sector.
Automotive Specifications
Dry
This plastic material has approval for 4 automotive specifications from the following agencies (the number in parentheses shows the number of specifications for that agency): ASTM (2), GM (2).
Agency Ratings
Dry
This plastic material has 1 certifications from the following agencies (the number in parentheses shows the number of certifications for that agency): DVGW (1).
Conditioned
This supplier and product may also be known by these terms: Gryvory

Product names can be difficult to match. You may have searched any one of these terms to find this product: Grivory® GV-2H, Grivory GV2H, Grivory® , Grivory, GrivoryGV2H, GV, GV 2 H, GV-2H, GV2H, GV:2H, GV/2H, GV+2H, GV_2H, GV 2H, GV2, 2H, Polyamide 66 + PA 6I/X, Polyamide 66 PA 6IX, Polyamide 66 + PA 6I:X, Polyamide 66 + PA 6I+X, Polyamide 66 + PA 6I-X, Polyamide 66 + PA 6I_X, Polyamide 66 + PA 6I X, Polyamide 66 : PA 6I/X, Polyamide 66 / PA 6I/X, Polyamide 66 - PA 6I/X, Polyamide 66 _ PA 6I/X, Polyamide 66 PA 6I/X, Nylon 66+Nylon 6I/X, Nylon 66Nylon 6IX, Nylon 66+Nylon 6I:X, Nylon 66+Nylon 6I+X, Nylon 66+Nylon 6I-X, Nylon 66+Nylon 6I_X, Nylon 66+Nylon 6I X, Nylon 66:Nylon 6I/X, Nylon 66/Nylon 6I/X, Nylon 66-Nylon 6I/X, Nylon 66_Nylon 6I/X, Nylon 66 Nylon 6I/X, Polyamide, Nylon, EMS-Grivory, Polyamide66PA6IX, Polyamide 66 PA 6I_X, Polyamide 66 PA 6I X, Polyamide 66 _ PA 6IX, Nylon66Nylon6IX, Nylon 66Nylon 6I_X, Nylon 66Nylon 6I X, Nylon 66_Nylon 6IX, Nylon 66 Nylon 6IX, Polyamide66PA6I_X, Polyamide66_PA6IX, Nylon66Nylon6I_X, Nylon66_Nylon6IX, 2GV
Notes
1Typical properties: these are not to be construed as specifications.
2Long Term
3Short Term
410°C/min
 
IDES
Copyright © 2012 IDES
The information presented on this datasheet was acquired by IDES from the producer of the material. IDES makes substantial efforts to assure the accuracy of this data. However, IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.