IDES Prospector Already have an account? Login Here

IDES

TAROLOX 10 G4 DX03

Polybutylene Terephthalate

Glass Fiber Reinforcement, 20%

Supplied by Taro Plast S.p.A.

The technical datasheet with complete property values for TAROLOX 10 G4 DX03 is available to members of the Prospector Plastics Database.
Register to view full datasheet.
Register to View Full Datasheet
General  
Material Status 
  • Commercial: Active
Availability 
  • Europe
Filler / Reinforcement 
  • Glass Fiber Reinforcement, 20% Filler by Weight
Additive 
  • Heat Stabilizer
  • Mold Release
 
Features 
  • Good Dimensional Stability
  • Good Flow
  • Good Mold Release
  • Good Surface Finish
  • Heat Stabilized
  • Self Extinguishing
  • Tracking Resistant
Appearance 
  • Colors Available
Forms 
  • Pellets
Processing Method 
  • Injection Molding
Physical
Nominal Value
Unit
Test Method
Specific Gravity
     
--
 
ASTM D792
--
g/cm³
ISO 1183
Molding Shrinkage
    ASTM D955
Flow
in/in
 
Across Flow
in/in
 
Water Absorption
     
73°F, 24 hr
%
ASTM D570, ISO 62
Saturation
%
ASTM D570
Saturation, 73°F
%
ISO 62
Mechanical
Nominal Value
Unit
Test Method
Tensile Modulus
psi
ASTM D638, ISO 527-2
Tensile Strength (Break)
psi
ASTM D638, ISO 527-2
Tensile Elongation (Break)
%
ASTM D638, ISO 527-2
Flexural Modulus
psi
ASTM D790, ISO 178
Flexural Strength
     
--
psi
ISO 178
Break
psi
ASTM D790
Impact
Nominal Value
Unit
Test Method
Charpy Notched Impact Strength (73°F)
ft·lb/in²
ISO 179
Notched Izod Impact (73°F, 0.126 in)
ft·lb/in
ASTM D256
Hardness
Nominal Value
Unit
Test Method
Rockwell Hardness (R-Scale)
 
ASTM D785
Thermal
Nominal Value
Unit
Test Method
Deflection Temperature Under Load
     
66 psi, Unannealed
°F
ASTM D648, ISO 75-2/B
264 psi, Unannealed
°F
ASTM D648, ISO 75-2/A
Max. Continuous Use Temperature
°F
ASTM D794
Vicat Softening Temperature
     
--
°F
ASTM D1525 2, ISO 306/A50 2
--
°F
ASTM D1525 3, ISO 306/B50 3
Melting Temperature
°F
 
CLTE - Flow (-22 to 86°F)
in/in/°F
ASTM D696
Electrical
Nominal Value
Unit
Test Method
Volume Resistivity
ohm·cm
ASTM D257
Dielectric Strength (0.0787 in)
V/mil
ASTM D149
Comparative Tracking Index
    IEC 60112
Solution A
V
 
Solution B
V
 
Flammability
Nominal Value
Unit
Test Method
Flame Rating - UL
    UL 94
0.0630 in
 
 
0.126 in
 
 
Glow Wire Ignition Temperature (0.0787 in)
°F
IEC 60695-2-13
Oxygen Index
%
ASTM D2863
Additional Information
Granule Humidity, TARO 002: <0.05%
Ball Pressure Test, VDE 0470: 215°C
Continuous Service Temperature, UL 94 746B: 75°C
Continuous Service Temperature, IEC 216, 130 hr: 90°C
Continuous Service Temperature, IEC 216, 160 hr, short term: 130°C
Density, ISO 118: 1.51 to 1.53 Mg/m³
Density. ASTM D792: 1.51 to 1.53 Mg/m³
Notched Izod Impact Strength , ISO 180, 23°C: 65 J/m
Charpy Impact Strength, ASTM D256, 23°C, 4mm: 5.5 kJ/m²
Volume Resistivity, ASTM D257: >1e15 ohm-cm
Related Terminology
Product names can be difficult to match. You may have searched any one of these terms to find this product: TAROLOX 10 G4 DX03, TAROLOX , TAROLOX10G4DX03, 10 G 4 DX 03, 10 G4 DX03, 10G, G4, 4DX, DX03, 10G4DX03, Polybutylene Terephthalate, PBT, Polyester, Taro Plast, PolybutyleneTerephthalate, G10
Features
Features may also be described by the following terms: Self Extinguishing, Self-Extinguishing, Good Flow, Good Surface Finish, Good Dimensional Stability, Dimensionally Stable, Heat Stabilized, Heat-ageing Stabilized, Heat Ageing Stabilized, Heat-aging Stabilized, Heat Aging Stabilized, Good Mold Release, Easy Release, Good Demolding.
Injection
Nominal Value
Unit
 
Drying Temperature
     
--
°F
 
Pre-heater
°F
 
Drying Time
     
--
hr
 
Pre-heater
hr
 
Processing (Melt) Temp
°F
 
Mold Temperature
°F
 
Injection Rate
 
 
Notes
1Typical properties: these are not to be construed as specifications.
2Rate A (50°C/h), Loading 1 (10 N)
3Rate A (50°C/h), Loading 2 (50 N)
 
IDES
Copyright © 2012 IDES
The information presented on this datasheet was acquired by IDES from the producer of the material. IDES makes substantial efforts to assure the accuracy of this data. However, IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.