Product Description
Delrin® 311DP BK402 is a medium high viscosity acetal homopolymer with improved thermal stability and modifications for more precise molding(reduced warpage, less shrinkage, fewer voids).
General  
Material Status 
  • Commercial: Active
Availability 
  • Asia Pacific
  • Europe
  • North America
Features 
  • Fatigue Resistant
  • Good Creep Resistance
  • Good Dimensional Stability
  • Good Impact Resistance
  • High Stiffness
  • High Strength
  • Homopolymer
  • Medium-high Viscosity
  • Ultrasonic Weldable
Uses 
  • Automotive Interior Parts
  • Cast Film
  • Engineering Parts
  • Fasteners
  • Gears
  • Sheet
  • Tubing
  • Wire & Cable Applications
RoHS Compliance 
Automotive Specifications 
  •  1
Appearance 
  • Black
Processing Method 
  • Cast Film
  • Extrusion
  • Profile Extrusion
  • Sheet Extrusion
 
Part Marking Code (ISO 11469)
  • >POM<
Resin ID (ISO 1043)
  • POM
Physical
Nominal Value
Unit
Test Method
Density
g/cm³
ISO 1183
Melt Mass-Flow Rate (MFR) (190°C/2.16 kg)
g/10 min
ISO 1133
Mechanical
Nominal Value
Unit
Test Method
Tensile Modulus (73°F)
psi
ISO 527-2
Tensile Stress (Yield, 73°F)
psi
ISO 527-2
Tensile Strain
     
Yield, 73°F
%
ISO 527-2
Break, 73°F
%
ISO 527-2/50
Nominal Tensile Strain at Break (73°F)
%
ISO 527-2
Impact
Nominal Value
Unit
Test Method
Charpy Notched Impact Strength
    ISO 179/1eA
-22°F
ft·lb/in²
 
73°F
ft·lb/in²
 
Thermal
Nominal Value
Unit
Test Method
Heat Deflection Temperature (264 psi, Unannealed)
°F
ISO 75-2/A
Melting Temperature 3
°F
ISO 11357-3
Flammability
Nominal Value
Unit
Test Method
Flame Rating - UL
    UL 94
0.0295 in
 
 
0.0591 in
 
 
0.118 in
 
 
Flammability Classification
    IEC 60695-11-10, -20
0.0295 in
 
 
0.0591 in
 
 
0.118 in
 
 
UL
Nominal Value
Unit
Test Method
RTI Str
    UL 746
0.0295 in
°F
 
0.0591 in
°F
 
0.118 in
°F
 
RTI Imp
    UL 746
0.0295 in
°F
 
0.0591 in
°F
 
0.118 in
°F
 
RTI Elec
    UL 746
0.0295 in
°F
 
0.0591 in
°F
 
0.118 in
°F
 
Related Terminology
This supplier and product may also be known by these terms: Derlin

Product names can be difficult to match. You may have searched any one of these terms to find this product: Delrin® 311DP BK402, Delrin 311DP BK402, Delrin® , Delrin, Delrin311DPBK402, 311 DP BK 402, 311DP BK402, 311DP, DPBK, BK402, 311DPBK402, Acetal Homopolymer, Acetal Homopolymer, Acetal (POM) Homopolymer, Acetal POM Homopolymer, Acetal, pom, DuPont, AcetalPOMHomopolymer, DP311
Features
Features may also be described by the following terms: Good Creep Resistance, Creep Resistant, Good Dimensional Stability, Dimensionally Stable, Good Impact Resistance, High Strength, Medium-High Viscosity, Medium Viscosity, High Viscosity, Medium High Viscosity, High Stiffness, Ultrasonic Weldable.
Uses
Uses may also be described by the following terms: Cast Film, Tubing, Tube, Engineering Parts, Wire and Cable Applications, Wire & Cable Applications.
Automotive Specifications
This plastic material has approval for 3 automotive specifications from the following agencies (the number in parentheses shows the number of specifications for that agency): CHRYSLER (1), FORD (1), GM (1).
Injection
Nominal Value
Unit
 
Drying Temperature
°F
 
Drying Time
hr
 
Suggested Max Moisture
%
 
Processing (Melt) Temp
°F
 
Melt Temperature, Optimum - Injection Molding
°F
 
Mold Temperature
°F
 
Mold Temperature, Optimum - Injection Molding
°F
 
Drying Recommended
 
 
Notes
1This specification is applicable for the Americas region.
2Typical properties: these are not to be construed as specifications.
310°C/min
 
IDES
Copyright © 2012 IDES
The information presented on this datasheet was acquired by IDES from the producer of the material. IDES makes substantial efforts to assure the accuracy of this data. However, IDES assumes no responsibility for the data values and strongly encourages that upon final material selection, data points are validated with the material supplier.