IDES > Generics > Diallyl Phthalate (DAP) > Properties / Processing

Diallyl Phthalate (DAP) Typical Properties Generic DAP - Glass Fiber Reinforcement

Apply for Access to 85,000 Data Sheets •  Share this page Share this page
IDES LinkedIn Group   Follow IDES on Twitter       
  • Generic DAP - Glass Fiber Reinforcement
  • Generic DAP - Glass Fiber, Long
  • Generic DAP - Mineral Filler
  • Product Description
    This data represents typical values that have been calculated from all products classified as: Generic DAP - Glass Fiber Reinforcement

    This information is provided for comparative purposes only.
    General  
    Material Status 
    • Commercial: Active
    Availability 
    • Africa & Middle East
    • Asia Pacific
    • Europe
    • Latin America
    • North America
    • South America
    Filler / Reinforcement 
    • Glass Fiber Reinforcement
    Physical
    Nominal Value
    Unit
    Test Method
    Specific Gravity
    1.82 to 1.92
     
    ASTM D792
    Bulk Factor
    2.3 to 6.0
     
    ASTM D1895
    Molding Shrinkage - Flow (73°F)
    0.0020 to 0.0031
    in/in
    ASTM D955
    Water Absorption (Saturation, 73°F)
    0.25 to 0.27
    %
    ASTM D570
    Mechanical
    Nominal Value
    Unit
    Test Method
    Tensile Strength
        ASTM D638
    Yield, 73°F
    7000 to 8010
    psi
     
    73°F
    10900 to 12000
    psi
     
    Flexural Modulus (73°F)
    1.70E+6 to 1.81E+6
    psi
    ASTM D790
    Flexural Strength
        ASTM D790
    73°F
    17900 to 19000
    psi
     
    Yield, 73°F
    14000 to 15100
    psi
     
    Compressive Strength (73°F)
    21600 to 27200
    psi
    ASTM D695
    Impact
    Nominal Value
    Unit
    Test Method
    Notched Izod Impact (73°F)
    0.51 to 4.6
    ft·lb/in
    ASTM D256
    Thermal
    Nominal Value
    Unit
    Test Method
    Deflection Temperature Under Load (264 psi, Unannealed)
    399 to 526
    °F
    ASTM D648
    CLTE - Flow
         
    --
    9.9E-6 to 0.000014
    in/in/°F
    ASTM D696
    --
    0.000010 to 0.000012
    in/in/°F
    ASTM E831
    Thermal Conductivity (73°F)
    1.9 to 2.5
    Btu·in/hr/ft²/°F
    ASTM C177
    Electrical
    Nominal Value
    Unit
    Test Method
    Dielectric Strength (73°F)
    350 to 450
    V/mil
    ASTM D149
    Dielectric Constant (73°F)
    3.50 to 4.40
     
    ASTM D150
    Dissipation Factor (73°F)
    0.0088 to 0.016
     
    ASTM D150
    Arc Resistance
    130 to 180
    sec
    ASTM D495
    Flammability
    Nominal Value
    Unit
    Test Method
    Oxygen Index
    26 to 50
    %
    ASTM D2863
    UL
    Nominal Value
    Unit
    Test Method
    RTI Str
    266 to 269
    °F
    UL 746
    RTI Imp
    266 to 269
    °F
    UL 746
    RTI Elec
    266 to 269
    °F
    UL 746
    Injection
    Nominal Value
    Unit
     
    Processing (Melt) Temp
    235 to 303
    °F
     
    Injection Notes
    This data represents typical values that have been calculated from all products classified as: Generic DAP - Glass Fiber Reinforcement

    This information is provided for comparative purposes only.
    Notes
    1Typical properties: these are not to be construed as specifications.
     
    1. Products
    2. Advertising
    3. About
    4. Contact
    ©1986- IDES