IDES > Generics > Fluoropolymer (Fluoropolymer) > Properties / Processing

Fluoropolymer (Fluoropolymer) Typical Properties Generic ETFE

Apply for Access to 85,000 Data Sheets •  Share this page Share this page
IDES LinkedIn Group   Follow IDES on Twitter       
Product Description
This data represents typical values that have been calculated from all products classified as: Generic ETFE

This information is provided for comparative purposes only.
General  
Material Status 
  • Commercial: Active
Availability 
  • Asia Pacific
  • Europe
  • North America
  • South America
 
Physical
Nominal Value
Unit
Test Method
Specific Gravity
1.69 to 1.75
 
ASTM D792
Apparent Density
0.74 to 1.30
g/cm³
ASTM D1895
Melt Mass-Flow Rate (MFR) (297°C/5.0 kg)
2.3 to 30
g/10 min
ASTM D1238
Water Absorption (73°F, 24 hr)
0.0070 to 0.030
%
ASTM D570
Mechanical
Nominal Value
Unit
Test Method
Tensile Strength
    ASTM D638
Yield, 73°F
4340 to 6630
psi
 
73°F
4950 to 6700
psi
 
Tensile Elongation (Break, 73°F)
290 to 450
%
ASTM D638
Flexural Modulus (73°F)
75000 to 185000
psi
ASTM D790
Thermal
Nominal Value
Unit
Test Method
Melting Temperature
507 to 514
°F
 
CLTE - Flow
0.000050 to 0.000074
in/in/°F
ASTM D696
Electrical
Nominal Value
Unit
Test Method
Volume Resistivity (73°F)
9.8E+16 to 1.0E+17
ohm·cm
ASTM D257
Dielectric Strength (73°F)
1700 to 1800
V/mil
ASTM D149
Dielectric Constant (73°F)
2.55 to 2.60
 
ASTM D150
Dissipation Factor (73°F)
0.00060 to 0.0090
 
ASTM D150
Flammability
Nominal Value
Unit
Test Method
Oxygen Index
31 to 32
%
ASTM D2863
Notes
1Typical properties: these are not to be construed as specifications.
 
  1. Products