| Product Description | ||||
|
This data represents typical values that have been calculated from all products classified as: Generic PI, TS
This information is provided for comparative purposes only. |
||||
| General | ||||
|
Material Status
|
|
|||
|
Availability
|
|
|||
| Physical |
Nominal Value
|
Unit
|
Test Method
|
|
Specific Gravity
|
|||
|
--
|
1.33 to 1.68
|
|
ASTM D792 |
|
--
|
1.42 to 1.53
|
g/cm³
|
ASTM D1505 |
|
Water Absorption (73°F, 24 hr)
|
0.010 to 2.9
|
%
|
ASTM D570 |
| Mechanical |
Nominal Value
|
Unit
|
Test Method
|
|
Tensile Strength (73°F)
|
10300 to 22400
|
psi
|
ASTM D638 |
|
Tensile Elongation (Break, 73°F)
|
1.0 to 7.7
|
%
|
ASTM D638 |
|
Flexural Modulus (73°F)
|
360000 to 1.17E+6
|
psi
|
ASTM D790 |
|
Flexural Strength (73°F)
|
12800 to 36300
|
psi
|
ASTM D790 |
|
Compressive Modulus
|
200000 to 455000
|
psi
|
ASTM D695 |
|
Compressive Strength (73°F)
|
3000 to 34800
|
psi
|
ASTM D695 |
|
Deformation Under Load (73°F)
|
0.0263 to 0.105
|
%
|
ASTM D621 |
| Films |
Nominal Value
|
Unit
|
Test Method
|
|
Film Thickness - Tested
|
0.95 to 3.1
|
mil
|
|
|
Secant Modulus - MD
|
405000 to 460000
|
psi
|
ASTM D882 |
|
Tensile Strength - MD (Break)
|
27800 to 35000
|
psi
|
ASTM D882 |
|
Tensile Elongation - MD (Break)
|
72 to 95
|
%
|
ASTM D882 |
|
Elmendorf Tear Strength - MD
|
6.8 to 38
|
g
|
ASTM D1922 |
| Impact |
Nominal Value
|
Unit
|
Test Method
|
|
Notched Izod Impact (73°F)
|
0.34 to 2.2
|
ft·lb/in
|
ASTM D256 |
| Hardness |
Nominal Value
|
Unit
|
Test Method
|
|
Rockwell Hardness (73°F)
|
12 to 95
|
|
ASTM D785 |
| Thermal |
Nominal Value
|
Unit
|
Test Method
|
|
Deflection Temperature Under Load (264 psi, Unannealed)
|
464 to 680
|
°F
|
ASTM D648 |
|
Glass Transition Temperature (DSC)
|
248 to 680
|
°F
|
DSC |
|
CLTE - Flow
|
0.000015 to 0.000027
|
in/in/°F
|
ASTM D696 |
| Electrical |
Nominal Value
|
Unit
|
Test Method
|
|
Surface Resistivity
|
4.1E+5 to 1.0E+16
|
ohm
|
ASTM D257 |
|
Volume Resistivity (73°F)
|
9.4E+7 to 5.8E+15
|
ohm·cm
|
ASTM D257 |
|
Dielectric Strength (73°F)
|
390 to 7800
|
V/mil
|
ASTM D149 |
|
Dielectric Constant (73°F)
|
2.70 to 3.62
|
|
ASTM D150 |
|
Dissipation Factor (73°F)
|
0.00080 to 0.0033
|
|
ASTM D150 |
| UL |
Nominal Value
|
Unit
|
Test Method
|
|
RTI Str
|
122 to 410
|
°F
|
UL 746 |
|
RTI Imp
|
122 to 266
|
°F
|
UL 746 |
|
RTI Elec
|
122 to 464
|
°F
|
UL 746 |
| Notes |
| 1Typical properties: these are not to be construed as specifications. |