Dielectric Strength - ASTM D149
Purchase and download official ASTM standards today!
Voltage per unit thickness at which a material will conduct electricity. The higher the value, the more electrically insulating a material is.
The test material is placed between two electrodes. Voltage is applied in a specified manner until the material experiences dielectric breakdown, an electrical burn-through (puncture) of the test specimen. Testing is performed using one of three methods as outlined below.
| Method |
Name |
Description |
| A |
Slow Rate-of-Rise |
Voltage is increased at a uniform rate until dielectric breakdown of material. |
| B |
Short-Time |
Voltage is increased from 50% of the breakdown voltage to the breakdown voltage at a uniform rate until dielectric breakdown of the material. |
| C |
Step-by-Step |
Voltage is increased from 50% of the breakdown voltage in equal increments for a specified time until dielectric breakdown of the material. |
Similar Standards
|