IEC 60695-11-10 Test Standard Explained
Share This Page
• Free Access to 80,000 Datasheets
|
||||||||||||||
Flammability Classification - IEC 60695-11-10Horizontal Testing (HB) - Method AProcedure: A specimen is supported in a horizontal position and is tilted at 45°. A flame is applied to the end of the specimen for 30 seconds or until the flame reaches the 1 inch mark. If the specimen continues to burn after the removal of the flame, the time for the specimen to burn between the 1 and 4 inch marks are recorded. If the specimen stops burning before the flame spreads to the 4 inch mark, the time of combustion and damaged length between the two marks is recorded. Three specimens are tested for each thickness. ![]() Horizontal Flame Test
Vertical Testing (V-0, V-1, V-2) - Method BProcedure: A specimen is supported in a vertical position and a flame is applied to the bottom of the specimen. The flame is applied for ten seconds and then removed until flaming stops at which time the flame is reapplied for another ten seconds and then removed. Two sets of five specimens are tested. The two sets are conditioned under different conditions. ![]() Vertical Flame Test