Coefficient of Linear Thermal Expansion (CLTE) - ISO 11359-1,-2
The change in length per unit length of a material per degree of temperature change. CLTE is measured using a thermomechanical analyzer. The specimen is held in an enclosure and is contacted by a probe leading to a displacement sensor. A small force is applied to the specimen to keep the probe in contact with the specimen.
Thermomechanical Analyzer SetupThe enclosure is brought to a starting temperature. The temperature within the enclosure is increased at a uniform rate. The expansion of the specimen is measured by the displacement sensor over the temperature range of interest. CLTE (α) is calculated using the formula:
ISO 10350 NoteISO 10350 specifies that the test temperature range is to be from 23°C to 55°C. Similar StandardsProperty information for specific grades of resin are available in the Prospector. Join the IDES Network: Email Alerts • Blog • Twitter • LinkedIn |
||||