High Amp Arc Ignition (HAI) - UL 746
The number of arc rupture exposures necessary to ignite a material when they are applied at a standard rate on the surface of the material.
Performance Level Categories (PLC) were introduced to avoid excessive implied precision and bias.
| HAI Mean Number of Arcs |
PLC |
| 120 and greater |
0 |
| 60 through 119 |
1 |
| 30 through 59 |
2 |
| 15 through 29 |
3 |
| <15 |
4 |
|